Welcome: HWTAI-Realiable Supplier of Medical Consumables
Info@Hwtai.com 008615867460640

cPL Test Canine Panereatie Lipase Rapid Test

EHR ANA Test Canine Anaplasmosis Ehrlichiosis Combo Rapid Test is a indirect lateral flow immunochromatographic assay for the qualitative detection of Ehrlichia Canis antibody (Ehrli Ab) in dog’s serum or plasma. Assay Time: 5-10 min Sample: serum, plasma or whole blood

EMAIL

4.jpg


Introduction


cPL Test Canine Panereatie Lipase Rapid test is a lateral flow immunochromatographic assay for the qualitative detection of the canine pancreatic lipase (cPL) in dog’s serum, plasma or whole blood specimen, as an auxiliary examination of pancreatitis. Cut off: 200μg/L Assay Time: 5-10 minutes.


Product Name

cPL Test Canine Panereatie Lipase Rapid Test

Specimen

Serum, plasma or whole blood

Assay Time

5-10 minutes

MOQ

800 test kits

Delivery time

1 week after Get payment

Packing

10 test kits/Packing box

Shelf Life

18 months


Benefits

1. One-step whole blood, serum and plasma testing.

2. Simple operation, non-professional on-site inspection.

3. The detection process is fast, and the result will be displayed in about 15 minutes.

4. The test time is less than or equal to 10 seconds, and it can detect 270 samples per hour at the fastest.

5. The detection equipment is compact, easy to carry, mobile terminal operation, cloud platform quality control.

6. The detection sensitivity is high, comparable to that of enzyme-labeled kits.



ComponentsHe860846ba0d9496eb7feb5bed917cbbfX1.jpg


• Test devices

• Droppers

• Single Buffer

• IFU

Principle


The Canine cPL Test is based on sandwich method lateral flow immunochromatographic assay. The test card has a testing window for the observation of assay running and result reading. The testing window has an invisible T (test) zone and a C (control) zone before running the assay. When the treated sample was applied into the sample hole on the device, the liquid will laterally flow through the surface of the test strip and react with the pre-coated cPL monoclonal antibodies. If the concentration of cPL is exceeding the cutoff , a visible T line will appear. The C line should always appear after a sample is applied, which indicates a valid result. By this means, the device can accurately indicate the presence of cPL antigen in the specimen.

Strage and stablity

The kit can be stored at room temperature (2-30°C). The test kit is stable through the expiration date (18 months) marked on the package label. DO NOT FREEZE. Do not store the test kit in direct sunlight.

 

Other Items

Canine Rapid test Kits

Canine   Distemper Virus Antigen Test

Canine   Parvo/Corona Ag Combo Test

Canine   Distemper Virus Antibody Test

Canine   Anaplasma Antibody Test

Canine Parvo   Virus Antigen Test

Canine   Rotavirus Antigen Test

Canine Parvo   Virus AntibodyTest

CPV/CDV   Antibody Combo Test

Canine   Influenza Virus Ag Rapid Test

Canine   Distemper/Adeno Ag Combo Test

Canine   Coronavirus Antigen Test

Canine   Parvo-Corona-Rota Virus Antigen Combo Test

Canine   Parainfluenza Virus Antigen Test

CPV/CCV/Giardia   Combo Test

Canine   Adenovirus II Antigen Test

Lyme Disease   Antibody Test

Canine   Adenovirus I Antigen Test

Pregnancy   Relaxin Test

Canine CRP   Test

Canine   Giardia Antigen Test

Canine   Toxoplasma Antibody Test

CDV/CPIV Ag   combo Test

Canine   Heartworm Antigen Test

Canine   Distemper/Adeno/Influenza Combo Test

Leishmania   canis Antibody Test

Canine   Infectious Hepatitis/Parvo Virus/Distemper Virus IgG combo test

Canine   Brucella Antibody Test

Canine   Ehrlichia/Anaplasma Combo Test

Ehrlichia   Canis Antibody Test

Ehrlichia/Lyme/Anaplasma   Combo Test

Canine   Leptospirosis Antibody Test

Ehrlichia/Lyme/Anaplasma/Heartworm   Combo Test

Babesia   gibsoni Antibody Test

Ehrlichia/Babesia/Anaplasma   Combo Test

Rabies   Antigen Test

Ehrlichia/Babesia/Anaplasma/Heartworm   Combo Test

Rabies   Antibody Test




Test Procedure

-Allow all materials, including specimen and test device, recover to 15-25℃ before running the assay.

- Take out the test card from the foil pouch and place it horizontally.

- Use the capillary dropper to suck specimen and place 1 drop (approx. 10μL) of the prepared specimen into sample hole “S” of the test card. Then drop 3 drops (approx. 90μL) of the assay buffer into the sample hole. Start the timer.

- Interpret the result in 5-10 minutes. Result after 10 minutes is considered as invalid.

lipase



INTERPRETATION OF ASSAY RESULT


- Positive (+): Whether the T line is clear or fuzzy, the "C" line and the region "T" line are present.

- Negative (-): Shows only the sharp C line. No T line.

- Invalid: no color lines in zone C. Whether the T line appears or not.


image.png

装箱发货图.jpg

INQUIRY